Specialized filters are measured with a photometer


Release time:

2025-04-28

Professional filter test steps are needed step by step after mastery and use, and today

Specialized filters are measured with a photometer

  Professional filter test steps are needed step by step after mastery and use, and today we will analyze the specific process from the nine steps for you, I believe that after reading you will have more confidence in the use of equipment.
  First, the professional filter test using the dust source for the 0.3mm single-dispersed phase DOP droplets, which the “amount” for the DOP-containing air turbidity.
  The measuring instrument is a photometer.
  Third, the beginning of the test, the DOP liquid will be heated into a vapor, the vapor in a particular environment will condense into tiny droplets, remove too large and too small droplets, leaving only about 0.3mm particles, the fog DOP into the air duct.
  Fourth, next you can measure the turbidity of the gas sample before and after the filter, thus determining the filter efficiency of the filter on the 0.3mm dust.
  Fifth, DOP method so far has a history of more than 50 years of development history, was the international measurement of the performance of filtration equipment in the commonly used methods.
  Sixth, by changing the dust parameters can also get other particle size DOP droplets, and in Europe and the United States 20 years ago to measure the ultra-high-efficiency filters 0.1mm DOP method of transformation, the measurement instrument has been changed to a condensation laser particle counter.
  Seven, you may be concerned about the test dust will contaminate the filter, so the manufacturer will use the customer in the test that does not contaminate the filter dust, for example, semiconductor chip factories do not like sodium salts, oil mist, DOP, and often require manufacturers to use solid particles of dust that they believe that the safety of the; and pharmaceutical factories require the use of outdoor atmospheric dust directly in the measurement of the filter.
  Eight, it should be noted that before and after the filter were sampled, containing salt spray gas samples so that the color of the hydrogen flame blue, increased brightness, and the brightness of the flame to determine the concentration of salt spray in the air, in order to determine the filter efficiency of the filter on the salt spray.
  Nine, in accordance with national standards for salt spray particles with an average diameter of 0.4mm, but at present the measured results of existing domestic devices are about 0.5mm.

Related News

Ocean Valve at Indo Water 2026

From August 11–13, 2026, Ocean Valve participated in Indo Water 2026 in Jakarta, Indonesia. We showcased our brass valves, copper fittings and fire protection products while connecting with customers and industry professionals from Indonesia and international markets.

2026-08-18

Choosing the Right Nickel Plated Brass Ball Valve for Your Needs

Choosing the Right Nickel Plated Brass Ball Valve for Your Needs Table of Contents 1. Introduction to Nickel Plated Brass Ball Valves 2. Advantages of Nickel Plated Brass 3. Common Applications for Nickel Plated Brass Ball Valves 4. How to Select the Right Size Valve 5. Installation Tips for Nickel Plated Brass Ball Valves 6. Maintenance and Care for Longevity 7. Troub

2026-10-12

Understanding the Benefits and Applications of Lockable Angle Ball Valves

Lockable angle ball valves are crucial components in various industrial applications, offering both functional versatility and enhanced safety. These valves are designed to provide reliable control over the flow of liquids and gases while also incorporating a locking mechanism to prevent unauthorized or accidental operation. This feature is particularly beneficial in environments where safety is p

2026-10-11

Why Investing in Gate Valve KITZ Type is Essential for Efficiency

Understanding Gate Valves and Their Importance in Industrial Applications Gate valves are crucial components in various industrial systems, serving to control the flow of liquids and gases. Among the various types of gate valves, the KITZ gate valve stands out due to its exceptional performance, durability, and efficiency. This article explores the significance of investing in KITZ gate valves for

2026-10-10

Understanding Brass Fire Hydrant Landing Valves: Essential Components for Fire Safety

Brass fire hydrant landing valves are specialized devices designed to control the flow of water from fire hydrants to fire hoses or other firefighting systems. Their primary function is to provide a reliable connection point for firefighters to access hydrant water supply in emergency situations. Typically made from high-quality brass, these valves are favored for their durability, resistance to c

2026-10-09

The Advantages of Using Oblique Hydrant Valves in Your Industrial Setup

The Advantages of Using Oblique Hydrant Valves in Your Industrial Setup Table of Contents 1. Introduction to Oblique Hydrant Valves 2. What Are Oblique Hydrant Valves? 3. Benefits of Using Oblique Hydrant Valves 3.1 Enhanced Safety Measures 3.2 Increased Operational Efficiency 3.3 High Reliability and Durability 3.4 Space-Saving

2026-10-08

Leave Messages

Any questions? Get in touch. We'd love to hear from you.

+86
  • +86 CN
Submit